td1580 integrated detection apparatus of meters for dc electrical energy -凯发k8国际

for more product details, please call us:0731-84930888

homeelectrical measurementdc energy calibrators

td1580 integrated detection apparatus of meters for dc electrical energy

适用于对直接接入式或间接接入式的直流电能表进行检定,或完成型式评价的大部分试验


电压 / 电流的输出准确度为 0.02 级 / 0.01 级可选

功率 / 电能的准确度为 0.02 级 / 0.05 级可选

overview

td1580 is an integrated apparatus applied to the verification and pattern evaluation of static meters for dc electrical energy. the accuracy of voltage/current energy is 0.01/0.02 optional, and electrical energy/power is 0.02/0.05. it is suitable for the verification, calibration and pattern evaluation of direct or indirect connected meters.

reference standards are gb/t 33708-2017 static meter for direct current energy and jjg 842-2017 verification regulation of electronic meters for measuring direct current electrical energy which tianheng participated in drafting .it is suitable for metrology institute, electric power department, manufacturers and users as the standard of dc power and electrical energy. 

applications ( class 0.02 )

 verification or calibration of direct connected meters of class 0.1 and below,and a majority of pattern evaluation

 verification or calibration of indirect connected meters of class 0.1 and below,and  a majority of pattern evaluation

features

 dc voltage output is 10 mv~1150 v,dc current output is 5 μa~120 a, which is suitable for the verification of direct connected meters, indirect connected meters.

 the verification of high voltage and large current is supported, and the small voltage and current output capacity is suitable for the start-up and latent test.

 dc small signal voltage output: 10 μv~4.4v,applied to the verification of indirect connected meters(type of voltage).

 auxiliary power supply: it can provide dc 24 v or ac 220 v power supply for electrical meters (type a).

 the voltage variation time of the power supply can be set arbitrarily within 20 ms~1 min to complete the voltage sag and short-term interruption test. (reference 5.3, 5.4)

 dc voltage source is a bipolar output, dc large voltage source, current source and small signal voltage source can be superimposed on ac components, of which frequency band is 40 hz ~ 1000 hz, amplitude and phase can be adjusted to carry out dc ripple effect test.

 the workbench is equipped with 3 stations to support simultaneous verification of 3 meters.

 proprietary softwaresemi-automatic and full-automatic verification is realized, so as data management and certificate export.

technical specifications

basic error test

dc voltage output

1

output characteristics:

 output range: ± ( 10 mv~1150 v ) 

 resolution: 0.001%*rg

 display: 7 digits

 protection: short-circuit protection, overload protection

dc current output

2

output characteristics:

 output range: ± ( 5 µa~120 a )

 resolution0.001%*rg

 display: 7 digits

 protection: open-circuit protection, overload protection

dc small signal voltage output

3

output characteristics:

 output range: ± ( 10 μv~4.4 v )

 resolution: 0.001%*rg

 display: 6 digits

 protectionshort-circuit protection, overload protection

 the shunt specifications and current-voltage ratio can be set, so the output value can be displayed as the voltage or current converted by the shunt.

dc electrical energy / power

 accuracy (apparatus of class 0.05): ± 0.05%*rd

   accuracy (apparatus of class 0.02): ± 0.02%*rd

 output of standard electrical energy pulse (high frequency): full scale value corresponds to 60 khz.

   output of standard electrical energy pulse(low frequency): full scale value corresponds to 6 hz.

   frequency jitter of output pulse: < 10 μs

 input of standard electrical energy pulse: high frequency pulse less than or equal to 150khz with the amplitude of 5 v can be received.

 the electrical energy error is automatically displayed with the resolution of 0.0001%.

dc ripple effect test

ripple on standard dc voltage source

4

output characteristics:

 output range: ( 10~110% )*rg ;0.2 vrms~220 vrms

 output range0.001%*rg

 display: 7 digits

 frequency and wave40 hz~1000 hz,sine wave

 accuracy of electrical energy/ power: ± 0.05%(class 0.02);± 0.1%(class 0.05)

 protection: short-circuit protection, overload protection

ripple on standard dc current source

5

output characteristics:

 output range: ( 10~120% )*rg ;0.2 marms~12 arms

 resolution: 0.001%*rg,

 display: 7 digits

 frequency and wave40 hz~1000 hz,sine wave

 phase between voltage: adjustable within 0.00º~359.99º

 accuracy of electrical energy/ power: ± 0.05%(class 0.02);± 0.1%(class 0.05)

 protection: open-circuit protection, overload protection

ripple on dc small signal voltage

6

output characteristics:

 output range: ( 10~120% )*rg ;0.5 mvrms~2.4 vrms

 resolution: 0.001%*rg,

 display: 7 digits

 frequency and wave: 40 hz~1000 hz,sine wave

 phase between voltageadjustable within 0.00º~359.99º

 accuracy of electrical energy/ power± 0.05%(class 0.02);± 0.1%(class 0.05)

 protection: overload protection

ripple on dc electrical energy

 voltage ripple factor: 0%~20.00%

 current ripple factor: 0%~20.00%

 absolute value of power factor: 0.5~1

 error limits of electrical energy variation caused by dc ripple: ± 0.05%(class 0.02);± 0.1%(class 0.05)

auxiliary power supply of verified meter

 the rated output voltage of dc power source is 24v and the range is 6v~32v, the maximum load current is 300ma for each station, and the accuracy of power consumption is higher than ±0.1va.

 the rated output voltage of ac power source is 220v and the range is 110v~286v, the maximum load current is 30ma for each station, and the accuracy of apparent power is higher than ±0.2va, active power is higher than ±0.2w.

 each station has the capacity of independent power consumption measurement.

voltage sag and short-time interruption test of ac power supply

7

ac power supply δu =100%,voltage interruption for 1s

8

ac power supply δu =100%, voltage interruption for 20ms

9

ac power supply δu =50%,voltage sag for 1 min

voltage sag and short-time interruption test of dc power supply

10

dc power supply δu =100%,voltage interruption for 1s

11

dc power supply δu =100%, voltage interruption for 0.3s

12

dc power supply δu =60%, voltage sag for 1s 

general specifications

 line powerac ( 220 ± 22 ) v,( 50 ± 2 ) hz

 operating environment15 ℃~30 ℃,40%~75% r·h,non-condensing

 storage environment-20 ℃~70 ℃,< 95% r·h,non-condensing

 dimensions(width*depth*height)2400 mm × 800 mm × 1100 mm (3 stations workbench )

 standard interfacers232

selection guidance

13