th2030 ultra-凯发k8国际

for more product details, please call us:0731-84930888

homeelectrical measurementelectrical standards

th2030 ultra-precise phase meter

全球第一款 8 位相位、频率测量标准仪器

交流电压输入:10 mv ~ 600 v,电流输入:0.1 ma ~ 12 a

频率范围:5.0000000 hz ~ 10.000000 khz,准确度达 ± 2 ppm

双通道电压输入,具有 u-i、u-u 两种相位测量模式,8 位显示 








overview

model th2030, an ultra-precise phase and frequency measuring instrument, is the first 8 digits phase meter in the world.

accurately measure ac voltage, current and frequency. dual channel voltage measurement loop, used for measuring the phase between voltage and current (u-i), voltage and voltage (u-u). the optimal accuracy of phase measurement is up to ±0.3 mdeg.

meet the requirements of jjg 440-2008 verification regulation of industry frequency single-phase phase meter.

applications

as a reference meter for high-precision phase and frequency measurement with maximum 8 digits display.

● calibrate the phase and frequency of ac standard source.

● detect various working phase meters and frequency meters in power system.

features

● input range of ac voltage is from 10 mv to 600 v, ac current is from 0.1 ma to 12 a.

● input range of frequency is from 5.0000000 hz to 10.000000 khz, the accuracy is up to ±2 ppm.

● dual channel voltage input with u-i and u-u phase measurement modes, 6 digits display.

● excellent accuracy of phase measurement at high frequency, the accuracy is better than ±0.03 º even at 10 khz.

● good electrical isolation and protection between measurement channels.

● large lcd touch screen, more intuitive of value display and easier operation.

● easy to build automatic detection system with the built-in rs-232 interface.

electrical specifications

ac voltage and ac current


1
output characteristics

● voltage measuring range: 10 mv to 600 v by dual channel

● current measuring range: 0.1 ma to 12 a

● range switching: automatic or manual

● display: 6 digits

● harmonic measurement: 2nd to 63rd

frequency measurement

● measuring range: 5.0000000 hz to 10.000000 khz

● minimum resolution: 1×10-7 hz

● 1 year uncertainty: ±2 ppm

● display: 8 digits

phase measurement


2
general specifications

● line power: 220 v ±22 v, 50 hz ±2 hz

 maximum power consumption: 400 va

● operating environment: 0 °c to +40 °c, 40 % to 75 % r·h, non-condensing

● storage environment: -20 °c to +70 °c, <95 % r·h, non-condensing

● communication: rs-232 interface


powered by © 2011-2013 inc.