td1570 verification apparatus of indirect connected meters for dc electrical energy -凯发k8国际

for more product details, please call us:0731-84930888

homeelectrical measurementdc energy calibrators

td1570 verification apparatus of indirect connected meters for dc electrical energy

专用于检定电压型电流间接接入式直流电能表的台体设备

准确度0.02级/ 0.05级可选

非常适合于制造商进行批量检测。


overview

td1570 is a set of apparatus specially applied to the verification of indirect connected meters for dc electrical energy. it is composed of standard dc voltage source, dc small signal voltage source, multi-station verification workbench, automatic verification software and so on. the accuracy of power/electrical energy is 0.02/0.05 optional, which supports automatic verification of 6~16 indirect connected meters for measuring dc electrical energy at the same time.

reference standards are gb/t 33708-2017 static meter for direct current energy and jjg 842-2017 verification regulation of electronic meters for measuring direct current electrical energy which tianheng participated in drafting .it is suitable for metrology institute, manufacturers, users of meters as the standard of dc power and electrical energy. 

applications (class 0.05)

● verification or calibration of indirect connected meters of class 0.2 and below

● verification or calibration of dc voltmeter 

features

●  dc voltage outputthe maximum value is 1150 v,which can meet the requirements of voltage test at 1.15un for 1 kv electrical energy meter.

● dc small signal voltage output: the maximum value is +4.4 v, which can be used as the current input (corresponding to shunt voltage) of indirect connected meters for dc energy, and meet the calibration requirements of forward and backward electrical energy meters.

the minimum output is as low as 10 μv, which is the basis for starting test of electrical energy meter.

● the annual accuracy of output voltage in millivolt level is 1 µv and the short-term stability is higher than 0.3 vrms/min,which meets the error test requirement of dc  meter with small load current (0.01in < i < 0.05in) under reference voltage.

● auxiliary power supply: it can provide dc 24 v or ac 220 v power supply for electrical meters (type a).

● clock verification: built in clock receiving module, it can display real-time clock and synchronize with beijing time.

● excellent load capacity: it ensures that the value is stable and accurate and works long hours at full load.

● high reliability: current, voltage and small signal voltage circuits are isolated from each other to ensure that the meter will not be damaged.

● man-machine function: the workbench is equipped with a control panel, so the operator can observe and control the output value by its lcd touch screen.

● multi-station verification workbench: automatic verification of 6-16 indirect connected meters is supported. the verification workbench is equipped with control panel, so the operator can observe and control the output value by its lcd touch screen, which facilitates manual verification. the high definition display window is embedded to facilitate users to observe and record the working status of the verified meters.

● the connecting wire of the four-wire small signal voltage and the meter is manufactured by professional technology, the thermoelectric voltage of which is less than 0.2μv, while the ordinary method is up to 20 μv.

 proprietary software: semi-automatic and full-automatic verification is realized, so as data management and certificate export.

technical specifications

dc voltage output

11

output characteristics:

● output range: 50 mv~1150 v

● resolution: 0.001%*rg

● display: 6 digits

● protectionshort-circuit protection, overload protection

dc small signal voltage output

22

output characteristics:

● output range: ± ( 10 μv~4.4 v )

 resolution: 0.002%*rg

 display: 6 digits

● protection: short-circuit protection, overload protection

● the shunt specifications and current-voltage ratio can be set, so the output value can be displayed as the voltage or current converted by the shunt.

dc electrical energy / power

● accuracy (apparatus of class 0.05): ± 0.05%*rd

   accuracy (apparatus of class 0.02): ± 0.02%*rd

● output of standard electrical energy pulse (high frequency): full scale value corresponds to 60 khz.

   output of standard electrical energy pulse(low frequency): full scale value corresponds to 6 hz.frequency jitter of output pulse: < 10 μs

● input of standard electrical energy pulse: high frequency pulse less than or equal to 150khz with the amplitude of 5 v can be received

● the electrical energy error is automatically displayed with the resolution of 0.0001%

● difference of each position: < ± 0.025% 

auxiliary power supply

 each station has 2 power supply modes: ac 220 v (isolation from power grid) and dc 24 v.

● ac 220 v load capacity: n*20 ma (n for station number), with replaceable fuse protection.

● dc 24 v load capacity: n*120 ma (n for station number), with short circuit and overload protection.

● notes: other types of power supply can be customized.

clock daily error

● standard clock accuracy: 2×10-7

● error display modes of s / d and ppm / ppb are supported

general specifications

● line powerac ( 220 ± 22 ) v,( 50 ± 2 ) hz

● maximum consumption: 600 va

● operating environment: 0 ℃~45 ℃,30%~80% r·h,non-condensing

● storage environment: -20 ℃~70 ℃,< 95% r·h,non-condensing

● dimensions(width*depth*height): 2800 mm × 700 mm × 1445 mm ( 16 stations workbench)

● standard interface: rs232、rs485

selection guidance

33

powered by © 2011-2013 inc.
网站地图