th2100 single-凯发k8国际

for more product details, please call us:0731-84930888

homeelectrical measurementelectrical standards

th2100 single-phase broadband power analyzer

精确获取电压、电流、功率、频率、相位、功率因数、谐波、噪声等电参量

测量:电压 100 mvrms ~ 1100 vrms,电流 200 μarms ~ 11 arms
工作频率: dc ~ 1 mhz,最佳准确度达 0.05 级
谐波分析:2 ~ 64 次谐波测量
其他功能:波形显示、相量图显示、电量稳定度测试等

overview

model th2100, accurately obtain electrical parameters such as voltage, current, power, frequency, phase, power factor, harmonic and noise, etc.

applied to optimize your products in terms of energy consumption, efficiency, reliability, emc and lcc. also applied to measure magnetic materials and calibrate magnetic measuring instruments by displaying voltage and current waveforms.

applications

 device measurement: iron cores, filters, inductors, ballasts, etc.

 parts and equipments: electric machinery, vfd, transformers, lighting equipments, etc.

 the interaction between the power supply network and the loads, such as their parameters.

features

 wide dynamic measuring range: voltage is from 100 mvrms to 1100 vrms, current is from 0.2 marms to 11 arms, working frequency is from dc to 1 mhz. the optimal accuracy of power measurement is up to class 0.1.

 group delay is <3 ns between voltage and current measurements, maintain the highest accuracy at high frequency and low power factor.

 oscilloscope function can display the waveforms of the measured electrical parameters in real time.

 measure phase displacement of v-i, and intuitively display in the form of phasor diagram.

 analyze the harmonics up to 64 times, and intuitively display in the form of histogram.

 the voltage circuit and the current loop are independent and isolated, the over-voltage and over-current protection ensure high reliability.

 large lcd touch screen, more intuitive of value display and easier operation.

electrical specifications

ac voltage and ac current

1

output characteristics

 voltage measuring range: 100 mvrms to 1100 vrms (3300 vpk)

 current measuring range: 0.2 marms to 11 arms (33 apk)

 range switching: automatic or manual

 display: 6 digits

 supported measurement functions: rms, ave and pk.

ac power measurements

3

frequency and phase measurements

4

general specifications

 line power: 220 v ±22 v, 50 hz ±2 hz

 operating environment: 0 °c to +40 °c, 20 % to 85 % r·h, non-condensing

 storage environment: -20 °c to +70 °c, <80 % r·h, non-condensing

 communication: rs-232 interface

powered by © 2011-2013 inc.
网站地图