for more product details, please call us:0731-84930888

homeelectrical measurementthree-phase ac&dc calibrators

td4510 calibrator for three-phase apparatuses

适用于校准交流采样装置、交直流变送器、三相交直流电测仪表、同周期表、三相电能表等设备


准确度: 0.02 级 / 0.05 级可选

交流采样检测:可进行虚负荷校验 ( 标准源 ),或实负荷校验 ( 钳形夹测电流 )

变送器检测:检测电量变送器的基本误差,兼具直流纹波及响应时间的测量功能

谐波功能:三相电量可加载 2 ~ 21 次,幅度 / 相位均可调的谐波,进行谐波影响量试验


overview

model td4510, a multi-function calibrator for electric power apparatuses. composed of three-phase and dc source, three-phase electrical parameters and dc signal measurement, electric energy measurement or other functions. the optional accuracy classes of three-phase power are 0.02 and 0.05.

applied to calibrate the ac sampling devices by real load or virtual load, and three-phase / dc apparatuses, ac electric energy meters, transmitters and synchrometers.

meet the requirements of q/gdw 1899-2013 verification regulation calibration specification of ac sampling electrical measuring equipment. (tunkia is involved in drafting)

applications

1

2

features

● ac sampling calibration: the virtual load calibration method is using by three-phase source, and the real load calibration method is using by measuring current with the clamp online.

● transmitters measurement: measure the basic error, dc ripple and the response time for the transmitters.

 harmonic output: the output can load 2nd to 21st standard harmonics with adjustable amplitude and phase to test harmonic influence on the checked meters.

● value adjustment method: fixed-point, rotary encoder, step and potentiometer (option).

● phasor diagram: freely adjust the phase between the three-phase electrical parameters, and intuitively display by phasor diagram.

● excellent human-computer interaction: large lcd touch screen display, touch and button operation modes, easy for users to measure manually.

● electric energy calibration (option): calibrate a single ac electric energy meter by the standard pulse i/o interface.

● periodic meters calibration (option): the fourth voltage output can calibrate the difference of amplitude, phase and frequency for periodic meters.

● proprietary software (option): support the calibration for the checked meters by semi-automatic or full-automatic, data management and report export.

electrical specifications

three-phase voltage / current output

3

output characteristics

● output range of voltage: 6 v to 456 v

 output range of current: 20 ma to 12 a

● resolution: 0.002 % of range

● display: 6 digits

● distortion: <0.2 %

● protection: short-circuit protection, open-circuit protection and overload protection.

frequency, phase, harmonic and symmetry output

4

three-phase power output

5

output characteristics

● output range of ac power: combination of ac voltage range and ac current range.

● range of power factor: -1.0000…0.0000…+1.0000

three-phase voltage / current measurement

6

measurement characteristics

● measuring range of voltage: 6 v to 456 v

● measuring range of current: 0.1 a to 6 a

● display: 6 digits

● frequency: the range is from 45 hz to 70 hz, and the accuracy is ±0.01 hz.

 phase: the range is from 0.000 ° to 359.999 °, and the accuracy is ±0.1 °.

three-phase power measurement

7

output characteristics

8

● output range of voltage: 10 mv to 660 v

● output range of current: 0.1 ma to 11 a

● resolution: 0.002 % of range

 display: 6 digits

● ripple coefficient: <1 %

● protection: short-circuit protection, open-circuit protection and overload protection.

dc small signal measurement

9

ac electric energy (option)

● accuracy of active electric energy:

±0.1 % of reading @ class 0.05; ±0.05 % of reading @ class 0.02;

● accuracy of reactive electric energy:

±0.2 % of reading @ class 0.05; ±0.1 % of reading @ class 0.02;

● output of standard electric energy pulse: full scale @ 60 khz

● input of standard electric energy pulse: frequency ≤1 khz, input level from 3 v to 12 v

● constant of electric energy meter: 1…1000000 imp./kwh or 1…1000000 imp./ws

the fourth voltage output (option for synchrometer calibration)

● output range of voltage: 100 v and 380 v

● output margin of voltage: 0 to 110 % of range

 resolution: 0.002 % of range

● accuracy in 1 year: ±0.05 % of range

● display: 6 digits

● frequency: the range is from 45.000 hz to 55.000 hz, and the resolution is 0.001 hz.

● phase: the range is from 0.00 ° to 359.99 °, the resolution is 0.01 °, the accuracy is ±0.1 °.

general specifications

● line power: 220 v ±22 v, 50 hz ±2 hz

● operating environment: 0 °c to +40 °c, 20 % to 80 % r·h, non-condensing

● storage environment: -20 °c to +70 °c, <80 % r·h, non-condensing

● dimensions (w × h × d): 430 mm × 190 mm × 415 mm

 weight: 18.5 kg

● communication: rs-232 interface