专用于测量电子式互感器比差、角差
交流电压与电流测量的准确度均为 0.01 级,频率 45 hz ~ 65 hz
在 50 hz / 60 hz 条件下,比差准确度达 ± 0.02%,相位移准确度达 ± 0.005°
支持多种单位显示:度、度分秒、弧度
overview
model td6300, a high-precision apparatus to measure the ratio difference and phase displacement for electronic instrument transformers. it has the function of vector measurement to the following parameters: the secondary voltage (maximum 120 v) and current (maximum 6 a) of standard transformers, the secondary ac output voltage (maximum 12 v) and current (maximum 1.2 a) of the detected electronic instrument transformers.
features
● the electronic voltage transformers or electronic current transformers are all supported for detecting.
● measure ac voltage, current and frequency, as well as measure the phase/ratio of v-v, v-i and i-i.
● the accuracy class of ac voltage or current measurement is 0.01 with a frequency of 45 hz to 65 hz.
● at 50 hz / 60 hz, the ratio difference measurement accuracy is up to ±0.02 %, and the phase displacement measurement accuracy is up to ±0.005 °.
● support for displaying multiple units, such as degree, degree-second-second and radian.
● all the input channels can automatically or manually switch the ranges.
● good electrical insulation and protection between all the input channels and measurement loops.
electrical specifications
ac voltage (u1) and current (i1) measurement
measurement characteristics
● measuring range of u1: 1 v to 120 v
● measuring range of i1: 5 ma to 6 a
● measuring range of frequency: 45 hz to 65 hz
● display: 7 digits
● protection: over-current protection
ac voltage (u2) and current (i2) measurement
measurement characteristics
● range switching: automatic or manual
● measuring range of u2: 1 mv to 12 v
● measuring range of i2: 0.1 ma to 1.2 a
● measuring range of frequency: 45 hz to 65 hz
● display: 7 digits
● protection: over-current protection
frequency and phase
ratio difference and phase displacement measurement
● accuracy of ratio difference: ±0.02 % (the input value ≥50 % of the range value, without the error caused by the standard transformers)
● accuracy of phase displacement: ±0.005 ° or 88 μrad (the input value ≥50 % of the range value, without the error caused by the standard transformers)
● frequency range: 45 hz to 65 hz
● notes: the unit of phase displacement can be degree or radian.
general specifications
● line power: 220 v ±22 v, 50 hz ±2 hz
● maximum power consumption: 80 va
● operating environment: 0 °c to +40 °c, r·h from 20 % to 85 %, non-condensing
● storage environment: -20 °c to +70 °c, r·h <95 %, non-condensing
● dimensions (w × h × d): 380 mm × 190 mm × 320 mm
● weight: 7 kg
● communication: rs-232 interface